create 관리자access_time 2024.10.30 13:40visibility 19assignment MW-class Load Testing Facility
[Test Motor]
Test Motor Capacity : 1.5 MW
Rated Torque : 8043 Nm
Rated Speed : 1781 RPM
Input Power : 3-phase, 690V, 60Hz
[Load Inverter]
Rated Output : 1.6 MW
Rated Input Voltage : 3AC 500~690V
DC Link Voltage : 675~1035V DC
Rated Current : 1620A(810A x 2)
Maximum Current : 2370A(1185A x 2)